Node Address Read; Alarm History - Mitsubishi Electric FR-A5NPA Instruction Manual

Profibus/dp communication option
Table of Contents

Advertisement

7.2.7 Node address read

The node address of the inverter can be read.
PNU
P918
Node address read Set node address is read.

7.2.8 Alarm history

The eight past error definitions of the inverter can be read.
PNU
P947.1 to
Error history No. 1
P947.8
read
P947.9 to
Error history No. 2
P947.16
read
P947.17 to
Error history No. 3
P947.24
read
P947.25 to
Error history No. 4
P947.32
read
P947.33 to
Error history No. 5
P947.40
read
P947.41 to
Error history No. 6
P947.48
read
P947.49 to
Error history No. 7
P947.56
read
P947.57 to
Error history No. 8
P947.64
read
<Error numbers>
Error
Definition
Number
00
No alarm
H
10
E.OC1
H
11
E.OC2
H
12
E.OC3
H
20
E.OV1
H
21
E.OV2
H
22
E.OV3
H
30
E.THT
H
31
E.THM
H
40
E.FIN
H
50
E.IPF
H
51
E.UVT
H
60
E.OLT
H
* Refer to the inverter manual for details of the error definitions.
PARAMETER DEFINITIONS - A500/F500 SERIES
Item
Item
P947.1
P947.2 to P947.8
P947.9
P947.10 to P947.16 :All 0
P947.17
P947.18 to P947.24 :All 0
P947.25
P947.26 to P947.32 :All 0
P947.33
P947.34 to P947.40 :All 0
P947.41
P947.42 to P947.48 :All 0
P947.49
P947.50 to P947.56 :All 0
P947.57
P947.58 to P947.64 :All 0
Error
Number
70
H
80
H
81
H
90
H
A0
H
A1
H
A2
H
A3
H
B0
H
B1
H
B2
H
C0
H
C1
H
51
Data Definition
Data Definition
:Error number
:All 0
:Error number
:Error number
:Error number
:Error number
:Error number
:Error number
:Error number
Error
Definition
Number
E.BE
C2
E.GF
D5
E.LF
D6
E.OHT
D7
E.OPT
D8
E.OP1
D9
E.OP2
DA
E.OP3
DB
E.PE
F1
E.PUE
F2
E.RET
F3
E.CPU
F6
E.CTE
F7
Data Type
Us16
Data Type
AUs16
AUs16
AUs16
AUs16
AUs16
AUs16
AUs16
AUs16
Definition
E.P24
H
E.MB1
H
E.MB2
H
E.MB3
H
E.MB4
H
E.MB5
H
E.MB6
H
E.MB7
H
E. 1
H
E. 2
H
E. 3
H
E. 6
H
E. 7
H

Advertisement

Table of Contents
loading

Table of Contents