DEVIreg™ Opti
•
The conduit should be flush with the floor surface, coun-
tersink the conduit if necessary and possible.
•
Route the conduit to the connection box.
•
The bending radius of the conduit must be min 50 mm.
Follow the steps below to mount the thermostat:
1.
Unpack thermostat
2.
Remove the front cover as showed
on Pic. 1.
3.
Connect the thermostat accor-
ding to the connection diagram.
The screen of the heating cable
must be connected to the earth
conductor of the power supply
cable by using a separate con-
nector.
Note: Always install the floor sensor in a conduit in
the floor.
Installation Guide
Pic. 1
L
S2 S1
L
LOAD
Max Load
Sensor
13(1) A
Made in P.R.C.
Danfoss A/S, 6430 Nordborg, Denmark
IP21
0T35
Ambient Temperature: 0-35°C
Standby maximum 0.5W
DEVIreg™ Opti
Pic. 2
N
N
LOAD
Mains 220-240V~
50Hz
9