Page 2
® devireg 316 is a thermostat for DIN rail attachment and has ® a height of 52 mm. devireg 316 is applied for control of room temperature, floor temperature, ventilation, cooling or as thermostat used for control of heat in gutters, etc. Installation: ®...
Page 3
Fig. 1 Temperature regulation I: In this case the thermostat is to be applied in connection with heating systems or refrigerating systems. The requested temperature is regulated in the scale with temperatures from -10°C to +50°C. Check that the hysteresis (Diff) is adjusted to what is requested (hysteresis at 1°C is recommended for control of room temperature).
Trouble-shooting Control of functioning: If heat is not turned on by activating the thermostat, check the RCD and fuses before contacting an authorized electrician. Trouble-shooting chart: Reserved for the electrician! Control of functioning: - Control mains voltage on clamps 5 and 6. - Tighten up load clamps 1 to 3.
Technical data Temperature range: -10°C to +50°C Working temperature: -10°C to +50°C Voltage: 180 - 250 V ~ 50 Hz Breaking power: 16 A Night set-back adjustable: 0.2ºC - 8ºC Differens adjustable: 0.2ºC - 6°C Cap class: IP 20 Regulation: range I -10ºC to +50°C range II...
Page 7
The Warranty: You have purchased a front page of the installation deviheat system, which we instruction in order to release ® are certain will increase your the warranty. home comfort and economy. The obligation of will be to repair or supply a new deviheat provides complete unit, free of charge to the...
Warranty Certificate The Warranty is granted to: Name: Address: Postal code: Phone: Please Observe! In order to obtain the Warranty, the following must be carefully filled in. See other conditions on the overleaf. Electrical Installation by: Installation date: Type of thermostat: Production code: Suppliers Stamp:...