Download Print this page

Advertisement

Installation Guide
DEVIreg™ 233
Electronic Thermostat
www.DEVI.com

Advertisement

loading

Summary of Contents for DEVI DEVIreg 233

  • Page 1 Installation Guide DEVIreg™ 233 Electronic Thermostat www.DEVI.com...
  • Page 3: Table Of Contents

    (0) 1 to 6 (each step corresponds to approximately 8°C). Furthermore, the thermostat has an LED indicator showing standby and heating periods. More information on this product can also be found at: devireg.devi.com Installation Guide...
  • Page 4: Technical Specifications

    DEVIreg™ 233 Technical Specifications Operation voltage 220-240V~, 50Hz Standby power consump- Max 1.7 W tion Relay: Resistive load Max 13A / 2990W @ 230V Inductive load cos φ= 0.3 max 1A Sensing units NTC 15kOhm at 25°C Sensing values: 0°C 42kOhm 25°C 15kOhm...
  • Page 5: Safety Instructions

    DEVIreg™ 233 IP class 41(only by vertical installa- tion) Protection class Class II - Dimensions 71x 44 x 31mm (in-wall depth: 20mm) Weight The product complies with the EN/IEC Standard "Automatic electrical controls for household and similar use": ▪ EN/IEC 60730-1 (general) ▪...
  • Page 6: Mounting Instructions

    DEVIreg™ 233 Please also note the following: ▪ The installation of the thermostat must be done by an authorized and qualified installer according to local regulations. ▪ The thermostat must be connected to a power supply via an all-pole disconnection switch. ▪...
  • Page 7 DEVIreg™ 233 In wet rooms, place the thermostat accord- ing to local regulation on IP classes. Do not install the thermostat in small bathrooms with poor ventilation, nor close to the toi- let due to the risk of condensed water and water splash.
  • Page 8 DEVIreg™ 233 Follow the steps below to mount the thermostat: 1. Open the thermostat: ▪ Detach the front cover by inserting a small screw- driver in the hole on top of the thermostat and lifting the cover outwards. ▪ Loosen the two screws and carefully detach the unit. 2.
  • Page 9: Settings

    DEVIreg™ 233 3. Mount and reassemble the thermostat. The thermostat is to be installed in a flush-mounting box or a surface-mounting box for the FUGA design. ▪ Put the unit back in place and tighten the screws in each side to fasten the thermostat. ▪...
  • Page 10: Warranty

    DEVIreg™ 233 How to change the minimum and maximum floor tem- peratures 1. Remove the front cov- 2. Move the adjustment sledges to the desired positions. 3. Put the front cover back in place. Warranty Y E A R Disposal Instruction Installation Guide...
  • Page 11 This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. DEVI and the DEVI logo- type are trademarks of Danfoss A/S.