Nibe F1145-5 Installer Manual page 59

Ground source
Table of Contents

Advertisement

Pull off the lock catches.
2
QM31
3
Disconnect the pipe connection at the shut-off valve
3
(QM31).
Remove the two screws.
4
Remove the connections from the base card (AA2)
5
using a screwdriver.
Disconnect the connectors (A) and (B) from the un-
6
derside of the base card cabinet.
Disconnect the connector (C) from the immersion
7
heater circuit board (AA1) using a screwdriver.
Disconnect the connector (D) from the joint circuit
8
board (AA100).
NIBE F1145
2
4
5
Carefully pull out the cooling module.
9
8
D
7
C
TIP
The cooling module is installed in reverse order.
NOTE
At reinstallation, the supplied O-rings must re-
place the existing ones at the connections to
the heat pump (see image).
F1145
QM34
5
6
A
B
9
QM33
QM32
Chapter 9 |
Service
59

Advertisement

Table of Contents
loading

Table of Contents