4. You can now select to take read outs for different
outdoor temperatures by turning the control knob
to the right or left and read off the corresponding
flow temperature.
5. Press the OK or Back button to exit read off mode.
TIP
Wait 24 hours before making a new setting, so
that the room temperature has time to stabilise.
If it is cold outdoors and the room temperature
is too low, increase the curve slope by one incre-
ment.
If it is cold outdoors and the room temperature
is too high, lower the curve slope by one incre-
ment.
If it is warm outdoors and the room temperature
is too low, increase the curve offset by one incre-
ment.
If it is warm outdoors and the room temperature
is too high, lower the curve offset by one incre-
ment.