Nibe F1145-5 Installer Manual page 50

Ground source
Table of Contents

Advertisement

Master/slave
master
Compressor
Master/slave: Select which heat pump the docking
setting is to be made for (if the heat pump is alone in
the system only master is displayed).
Compressor: Here you can select whether the com-
pressor is blocked, externally controlled via soft input or
standard (docked for example to pool heating, hot water
charging and heating the building).
Marking frame: Move around the marking frame using
the control knob. Use the OK button to select what you
want to change and to confirm setting in the options
box that appears to the right.
Workspace for docking: The system docking is drawn
here.
Symbol
Description
Compressor (blocked)
Compressor (externally controlled)
Compressor (standard)
Reversing valves for hot water, cooling re-
spectively pool control.
The designations above the reversing valve
indicate where it is electrically connected
(EB100 = Master, EB101 = Slave 1, CL11 =
Pool 1 etc.).
Common hot water charging from several
compressors. Controlled from the Master
heat pump.
Own hot water charging, only from selected
heat pump compressor. Controlled by relev-
ant heat pump.
Pool 1
Pool 2
50
Chapter 8 |
Control - Menus
Workspace for docking
docking5.2.3
s1
s2 s3 s4 s5 s6 s7 s8
F1145
Marking frame
Symbol
Description
Heating (heating the building, includes any
extra climate system)
Cooling
Menu 5.2.4 - accessories
Inform the heat pump which accessories are installed
here.
If the water heater is connected to F1145 hot water
charging must be activated here.
There are two ways of activating connected accessories.
You can either mark the alternative in the list or use the
automatic function "search installed acc.".
search installed acc.
Mark "search installed acc." and press the OK button to
automatically find connected accessories for F1145.
Caution
Certain accessories are not found with the
search function, but must be selected instead
in menu 5.4.
NOTE
Only mark the option for ground water pump
if the accessory AXC 40 is to be used to control
the circulation pump.
Menu 5.3 - accessory settings
The operating settings for accessories that are installed
and activated are made in the sub-menus for this.
Menu 5.3.1 - FLM
continuous pump op.
Setting range: on/off
Factory setting: off
time between defrosts
Setting range: 1 – 30 h
Default value: 10 h
months btwn filter alarms
Setting range: 1 – 12
Default value: 3
activate cooling
Setting range: on/off
Factory setting: off
continuous pump op.: Select for continuous operation
of the circulation pump in the exhaust air module.
NIBE F1145