After power-up, the JX3-AO4 module checks, if there is a valid operating
system.
The following conditions can lead to this error:
Terminating an operating system update
Hardware error of the JX3-AO4 module
The module reacts to the error by passing through the following stages:
Stage
1
The module outputs 0 at the analog outputs.
2
The D2 LED is shortly flashing red.
3
The version number in MR 9 is 255.x.0.0
x: Version of the bootloader
For fixing the root cause, proceed as follows:
Step
1
Carry out an operating system update via JetSym.
2
an operating system update cannot
be carried out,
For resetting the fault, proceed as follows:
Step
1
Restart the JX3 station.
Register Description – Locating of Errors (see page 134)
Description
Action
If ...
send the JX3-AO4 module to Jetter
AG for repair.