    CONTENTS INTRODUCTION.............. 3 INSTRUMENT OPERATION ..........5 Performing a Test (Analysis Mode) ........ 6 Entry of New Calibration Code ........9 Error Messages............10 Adjusting Optional Settings and Data Handling (Set-Up Mode) 11 COMPUTER INTERFACE ..........15 TECHNICAL INFORMATION ..........18 Operating Principle ............
  • Page 3: Introduction

    INTRODUCTION The Palintest ChloroSense is a precision instrument used with unique pre-calibrated disposable sensors*. It offers a simple, rapid, reagent-free method of analysing water for chlorine, removing almost all sources of technique dependence. The instrument is lightweight and portable for field or laboratory use.
  • Page 4 The sensor is designed for single use only. The surface of the sensor is highly sensitive. It should be handled by the edges or through the foil packaging only. Kit Contents ChloroSense Instrument Sensor Pack (x100 Sensors) Instructions Sample Bottle Sensor Carrying Box...
  • Page 5: Instrument Operation

    INSTRUMENT OPERATION The ChloroSense has three operating modes, the ANALYSIS mode, the SET-UP mode and the TEST mode. The instrument automatically engages SET-UP mode when connected to a PC, and ANALYSIS mode when battery powered and not connected to a PC. To access the TEST mode, see the calibration check standards instructions.
  • Page 6: Performing A Test (Analysis Mode)

    (See Entry of New Calibration Code - Page 9). 3 When the instrument passes all internal functional checks on start up, the screen displays the current batch code and prompts the user to insert a sensor. If start up fails, an error message is displayed.
  • Page 7 5 Press the blue lever to open the jaws of the sensor connector. Insert the exposed end of the  sensor, connecting tracks  uppermost, into the slot, and release the lever. The jaws will close to hold the sensor in place. Slide the foil pouch off to expose the sensor.
  • Page 8 Empty and rinse the sample Do not leave water container. within the instrument on completion of the test. 9 Press key to carry out a new test. If no key is pressed for five minutes, instrument automatically switches off to save power.
  • Page 9: Entry Of New Calibration Code

    Entry of New Calibration Code start change calibration using button. Slide the front catch to the right, and open the instrument case fully. Press the blue lever, and insert the contacts of the calibration chip fully into the   slot revealed.
  • Page 10: Error Messages

    Error Action 1 Remove sensor, dry the contacts (see overleaf). 2 Remove calibration chip. Press key and use Palintest check standards (CS 180). Remove and discard the sensor. Dry the contacts (see overleaf). Press key and start again with fresh sample and sensor.
  • Page 11: Adjusting Optional Settings And Data Handling (Set-Up Mode)

    If the contacts accidentally become wet, open the jaws with the blue lever and insert a dry tissue or Palintest Contact Drying Stick (CS 160). Wait a few seconds until it absorbs the water, then remove and insert the opposite end to check the contacts are dry.
  • Page 12 Enter SET-UP Mode To engage SET-UP mode, connect the instrument to a PC via the USB port using USB cable PT 747 or equivalent. USB Cable  Press and hold the power on/off button. Scroll through the menu of options using the keys, and press to select.
  • Page 13 Selectable Options Language Press to show the available languages. Scroll to highlight the required language. Press to select and return to the options list. Clear Log Press to select. Use keys to highlight [Yes] or [No]. Press to perform the action and return to the options list.
  • Page 14 Set Date Press to edit the displayed date. Use the keys to increment/ decrement the highlighted number. Use the keys to move the highlight to different numbers. Press to accept the new date and return to the options list. Date Format Press to select UK or US date format.
  • Page 15: Computer Interface

    COMPUTER INTERFACE The ChloroSense USB port, once connected to a PC, can be used to access data stored in the instrument log, or to up-grade the instrument software. When the ChloroSense is connected to a PC, it behaves like a removable hard drive or USB memory stick. Data Access 1 Connect the ChloroSense to a PC using the USB cable.
  • Page 16 4 Results are stored in the Log file, CLSE_LOG.TXT. 5 Copy the file to the PC to view and handle the data. 6 Open this file. Results appear as a text file. Each result appears on one line with spacing to allow easy opening in a spreadsheet program :- 7 To delete the results from the instrument memory, delete the log file on the hard drive window or from...
  • Page 17 Software Upgrade When new software is made available by Palintest, the ChloroSense may be upgraded. Files will be available by e-mail or on the Palintest website. 1 Connect the ChloroSense to a PC using the USB cable. 2 Press and hold the key until the title screen appears.
  • Page 18: Technical Information

    TECHNICAL INFORMATION Operating Principle The ChloroSense uses the electrochemical technique known as chronoamperometry. Chronoamperometry involves applying a fixed voltage to a working electrode and recording the resulting current-time dependence. The magnitude of the current is directly proportional to the concentration of chlorine in the test sample. ChloroSense sensors have two working electrodes, one that measures free chlorine and one that measures total chlorine.
  • Page 19: System Performance Characteristics

    System Performance Characteristics FREE CHLORINE TOTAL CHLORINE TEMPERATURE Analysis Time < 1 minute < 1 minute < 1 minute Precision Range 0.02 – 10.0 mg/l 0.05 – 75 mg/l 0 – 100°C* 0.02 up to 1 mg/l 0.01 up to 1.0 mg/l Resolution 0.1 from 1 –...
  • Page 20 Regulatory bodies have produced varying methods for determining the MDL and two are quoted here :- 1) UK Drinking Water Inspectorate (UK DWI) – The UK DWI method defines the MDL as the concentration for which there is a high probability that the determinand has been detected.
  • Page 21 ‘t’ value for a 99% confidence interval, if n = 7 tests, the ‘t’ value would be 3.14. The Palintest Research Laboratory have tested the instrument with both methods and have found that :- DWI Method: MDL (Free) = 0.05 mg/l...
  • Page 22: General Information

    GENERAL INFORMATION Technical Specification – Instrument Instrument Type Fixed voltage potentiostat Display Backlit, graphical LCD (42 x 22 mm), with five language options and direct-reading of results in mg/l User Selectable Set time and date, date format, Options display language, reset sample number and temperature units...
  • Page 23: Technical Specification - Sensors

    Real chlorine standards may be produced from calcium hypochlorite. Certified electronic standards may be obtained from Palintest Ltd in the Chlorine Check Standards Kit (CS 180). Power Supply The ChloroSense is designed to operate on alkaline batteries. The instrument features an automatic battery condition check as part of the analysis cycle.
  • Page 24 The instrument continues to function correctly for several tests, but the batteries should be replaced as soon as possible. When the power supplied by the batteries is insufficient to carry out a test, the instrument displays the warning message continually and will not carry out a test. The battery compartment, in the base of the instrument, is secured by four screws.
  • Page 25: Care And Maintenance

    On no account should solvents or abrasive materials be used to clean the instrument. Guarantee The Palintest ChloroSense is guaranteed for a period of two years from the date of purchase, excluding accidental damage or damage caused by unauthorised repair or misuse. Should repair be necessary, contact our Technical Services Department quoting the serial number shown on the instrument label.
  • Page 26: Reordering Information

    REORDERING INFORMATION Part Description Number ChloroSense Instrument with Pack of 100 CS 100 Sensors and Calibration Chip Pack of 100 Replacement ChloroSense CS 110 Sensors with Calibration Chip Pack of 500 Replacement ChloroSense CS 150 Sensors with Calibration Chip CS 160 Pack of 20 Contact Drying Sticks PT 747 USB Data Cable...