System Power Led; System Status Led; System Power Led Patterns During Normal; System Status Led Patterns During Normal - IBM Storage Networking SAN128B-6 Installation, Service And User Manual

Table of Contents

Advertisement

13. FC port 118 (QSFP 5) status LED
14. FC port 117 (QSFP 5) status LED
15. FC port 116 (QSFP 5) status LED
16. QSFP port 5
17. SFP+ (upper) port 58
18. SFP+ (upper) port 58 status LED
19. SFP+ (lower) port 60 status LED
20. SFP+ (lower) port 60

System power LED

Refer to the following table to interpret the system power status LED.
Table 10. System power LED patterns during normal operation
LED color
No light
Steady green

System status LED

Refer to the following table to interpret the system status LED.
Table 11. System status LED patterns during normal operation
LED color
No light
Steady green
Steady amber (for more than five
seconds—can take over a minute to
complete POST)
Steady amber (for more than a few
minutes)
Flashing amber/green
52
SAN128B-6 Installation, Service, and User Guide
Status of hardware
System is off or there is an internal
power supply failure.
System is on and power supplies are
functioning properly.
Status of hardware
System is off or there is no power.
POST and initialization is completed.
System is on and functioning
properly.
System is going through the
power-up process.
Unknown state, boot failed, or the
system is faulty.
Note: Once POST completes and the
switch has failed, steady amber may
result.
Attention is required. A number of
variables can cause this status,
including a single power supply
failure, a fan failure, or one or more
environmental ranges have been
exceeded.
Recommended action
Verify that system is powered on, the
power cables attached, and your
power source is live.
If the system power LED is not
green, the unit may be faulty.
Contact your solution provider.
No action required.
Recommended action
Verify that system is on and has
completed booting.
No action required.
No action required.
Perform the following steps:
1. Connect a serial cable to the
system.
2. Reboot the system.
3. Check the failure indicated on the
system console
4. Contact your solution provider.
Check the management interface and
the error log for details on the cause
of the status.
Contact your solution provider.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8960-f968960-n96

Table of Contents