Symptoms
Not turning on
Incorrect or fluctuating
temperature.
Probable Cause
Digital Mixer Valve
above cold water
storage cistern.
Air trapped in plumbing.
3. Shower Fitting/Other.
Blocked Showerhead.
Water pressure is low.
Fluctuating water
temperature.
2. Digital Mixer Valve.
No power to Digital
Mixer Valve.
Isolators closed.
Filters blocked.
3. Shower Fitting/Other
Blocked Showerhead.
1. Wireless Controller.
Controller out of range.
Radio interference.
32
Possible Remedy
Appliance is not
suitable for negative
head installation. Refer
to plumbing system
diagrams.
Rearrange pipework to
avoid airlock forming.
Refer to "Typical
Suitable Installations".
Clean/descale
showerhead.
Check flow rate is above
stated minimum. Refer
to "Specification".
Make sure inlet
temperature differentials
are sufficient.
Check electrical
connection and supply.
Open valves.
Clean filters.
Clean/descale
showerhead.
Repeat signal test.
Change controller
frequency channel.
Refer to User Guide -
"Control Frequency".