The end of the 15 mm pipework
from the outlet of the shower must
protrude through the finished wall
surface by 20 - 23 mm.
Note! The pipe work must protrude
through the wall between 20 - 23
mm from the finished surface of the
wall. If the pipe protrudes further
than 23 mm, it will prevent the
backplate nut from engaging with
the backplate. If necessary cut
the pipe to the correct length and
remove any burrs.
Fit an isolating valve (not supplied)
close to the Digital Mixer Valve for
ease of maintenance.
Loosely screw the backplate to the
RAC wallplate with the two screws
provided.
Place the RAC wallplate and
backplate assembly over the pipe.
Mark the position of the RAC
20 - 23 mm
wallplate and its fixing holes on the
wall.
Remove the screws and RAC
wallplate from the backplate.
Drill the two RAC wallplate fixing
holes. If necessary, make a recess
approximately 6 mm deep to accept
the RAC wallplate. Plug the two
fixing holes.