2.7.9
Setting the measuring system (G70, G71, G700, G710)
If a specific measuring system (inch/metric) is not explicitly defined in a synchronized action
with
synchronized action is executed takes effect:
●
●
The following rules apply when defining the measuring system in the synchronized action:
● If a measuring system is programmed in the condition part, this also takes effect in the
● If there is only a measuring system programmed in the action part, the system which is
● Different systems of units can be programmed in the condition and action parts.
● The measuring system programmed in the synchronized action has no effect on the part
Synchronized actions
Function Manual, 07/2012, 6FC5397-5BP40-3BA0
,
,
,
, the measuring system active in the part program at the time the
G70
G71
G700
G710
active in the part program:
G70/G71
– All the programmed position values are interpreted in the programmed measuring
system.
– All the read position data is interpreted in the parameterized basic system.
active in the part program:
G700/G710
– All the programmed position values are interpreted in the programmed measuring
system.
– All the read position data is interpreted in the parameterized basic system.
action part if a measuring system has not been specifically programmed there.
currently activated in the part program takes effect in the condition part.
program.
Detailed description
2.7 Actions in synchronized actions
87