Delete Distance-To-Go (Deldtg) - Siemens SINUMERIK 828D Function Manual

Synchronized actions
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

2.7.7

Delete distance-to-go (DELDTG)

The path distance-to-go can be deleted with the
can be deleted with the
After deletion of the distance-to-go, the value of the deleted distance-to-go can be read via a
system variable:
● Path distance-to-go: $AC_DELT
● Axial distance-to-go: $AA_DELT
Syntax
DELDTG
DELDTG(<axis 1>[,<axis 2>, ... ])
Meaning
Parameter
DELDTG
DELDTG(...)
<Axis n>
Supplementary conditions
Path-specific and axial delete distance-to-go
Path-specific and axial delete distance-to-go can only be executed in a non-modal
synchronized action (without specification of ID or IDS).
Path-specific delete distance-to-go
● The deletion of the path distance-to-go can only be executed in a non-modal
● The deletion of the path distance-to-go must not be used with active tool radius
Axial delete distance-to-go
Delete distance-to-go for indexing axes:
● Without Hirth tooth system: The axis is braked immediately
● With Hirth tooth system: The axis traverses to the next indexing position
Synchronized actions
Function Manual, 07/2012, 6FC5397-5BP40-3BA0
DELDTG (...)
Meaning
Deletion of the path distance-to-go
Deletion of the axial distances-to-go of the specified channel axes
:
Channel axis
synchronized action (without specification of ID or IDS).
compensation.
2.7 Actions in synchronized actions
command and axial distances-to-go
DELDTG
function in synchronized actions.
Detailed description
81

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d slSinumerik 840de sl

Table of Contents