Tub And Structure; Tub Trim (Some Models); Toe Kick; Junction Box And House Wiring Connection - GE GDF510PxJ Series Technical Service Manual

2015 plastic tub dishwasher
Table of Contents

Advertisement

The Tub and Structure section of this guide will
cover the toe kick, junction box, racks, leveling,
door balance, gaskets, trim (some models), main
control board, door, door components, as well
as the removing and separation of the screwless
appearance door. It will also cover the sump module
and removal. Details of the sump components
will be covered in the Circulation System or Drain
System sections of this guide.

Tub Trim (some models)

Some models include tub trim which clips to the
plastic tub to reduce sound levels and provides a
cleaner appearance to the installation.
Tub Trim
If the cutout prevents the dishwasher from being
fully installed, or if the trim rolls inward preventing
properly. The wiper edge must contact the cabinet
WARNING: GE Factory Service Technicians are
REQUIRED to follow Lockout / Tagout (LOTO) 6
Step Process prior to beginning repair.

Tub and Structure

Toe Kick

The toe kick is a decorative panel covering the
machine area of the dishwasher. The panel
provides a safety barrier, closing the front of the
dishwasher machine compartment. The toe kick
prevents injury from electrical components under
the dishwasher. To remove the panel, remove two
1/4 in. hex head screws and pull the panel away
from the dishwasher.
Insulation
Block

Junction Box and House Wiring Connection

The Junction Box is located behind the toe kick on
the right hand side of the dishwasher. The junction
box is where the 120 VAC house voltage connects to
the dishwasher. The dishwasher may be hardwired
or an optional cord may be installed (available
separately, Part #: WX09X70910), which plugs into
a wall outlet and connects to the harness plug into
the control (see Installation Guide). The cover is held
in place with a 1/4 in. hex head screw on the left
side, and tab on the right side. To remove the cover,
remove the screw and pull out and to left to release
the tab.
Toe Kick
– 20 –
Toe Kick
Insulation
Junction Box
Mounting Screw
Toe Kick
Screws
Ground Screws
Junction Box