Diverter Removal
1. Disconnect power to the dishwasher.
2. Remove the toe kick and insulation pieces, if
applicable.
3. Remove the door.
4. Remove the sump assembly.
5. Remove three 1/4 in. hex head screws securing
the diverter to the sump.
6. Loosen the clamp on the diverter inlet hose to
the circulation pump. Slide the diverter and hose
from the circulation pump.
Remove three 1/4 in.
hex head screws
7. Remove and discard the one time clamp.
Clamp Removal Tip: Use a small screwdriver
inserted into the ear of the clamp and move the
handle back and forth to loosen the clamp. The
clamp can be removed and discarded when the
component is removed. The Clamp Kit (Part #:
WD35X10382) has all six clamps located on the
sump module.
NOTE: Using a rinse aid or water on the diverter seal
will aid diverter installation.
Remove Clamp