Top Control Panel, Ui, Light Pipe And Buttons - GE GDF510PxJ Series Technical Service Manual

2015 plastic tub dishwasher
Table of Contents

Advertisement

Top Control Panel, UI, Light Pipe and Buttons

Access the UI, Control Covers, Buttons and Light
Pipe
1. Remove and separate the door.
2. Remove four 1/4 in. hex head screws.
3. The control and bottom cover will drop down
from the control panel.
4. The buttons, and light pipe with silicone pad will
be removed from the bottom cover to access
the UI.
5. The light pipe separates from the bottom cover
Top Cover
Console
Buttons
Light Pipe
UI
Bottom
Cover
Lens
6.
7. With the light pipe removed, the UI may be lifted
– 31 –
with tabs. A small screwdriver may be needed to
Tabs
release the remaining tabs (four each side).
out of the bottom cover.
When replacing UI control boards, the new UI
included with the replacement. If the personality
is not set by using the 4 jumpers, the buttons,
LED's or cycles will not function properly.
Diagnostics for both front and top control UI's
are found in the electronic section of this guide.