Circulation Motor And Pump Assembly; Diverter - GE GDF510PxJ Series Technical Service Manual

2015 plastic tub dishwasher
Table of Contents

Advertisement

Circulation Motor and Pump Assembly

The circulation motor is a DC Brushed Motor, it has
be properly checked on this motor because of the
To Remove Circulation Pump Motor Assembly:
1. Disconnect power to the dishwasher.
2. Remove the toe kick panel.
3. Remove the door.
4. Remove the sump module (see the Tub and
Structure section of this guide for sump removal
instructions).
5. Loosen the inlet and outlet wash motor clamps.
6.
remove and discard the one time use clamps.
WARNING: GE Factory Service Technicians are
REQUIRED to follow Lockout / Tagout (LOTO) 6
Step Process prior to beginning repair.
Loosen Clamps

Diverter

The Diverter is the key component which allows
low water use, by alternating water to the lower
spray arm or mid spray arm, bottle wash (some
models) and upper spray system (some models). It
is important to note the "Bypass" in the rear port of
the diverter, which allows for water to bypass the
check ball in the diverter as described in the next
section.
Bypass
Lower Spray Arm Port
Operation
The "Bypass" allows water to bypass the check
ball in the diverter as described in the next step.
pump operation. The check ball is at the bottom
of the diverter.
Outlet - Mid Spray Arm
Bottle Wash
Upper Sprayer
Bypass
Diverter Check Ball
– 54 –
Main Conduit
Release
Tab
Main Conduit
Port
Over Molded
Inlet Hose
Inlet
Outlet - Lower Spray Arm
Inlet
(Continued next page)