Nibe VVM 310 EMK Installer Manual page 59

Indoor module
Hide thumbs Also See for VVM 310 EMK:
Table of Contents

Advertisement

MENU 5.3.4 - SOLAR HEATING
start delta-T
Setting range: 1 - 40 °C
Default value: 8 °C
stop delta-T
Setting range: 0 - 40 °C
Default value: 4 °C
max. tank temperature
Setting range: 70 - 85 °C
Default value: 85 °C
max. solar collector temp.
Setting range: 80 - 200 °C
Default value: 125 °C
max solar pool temperature
Setting range: 10 - 80 °C
Default value: 30 °C
anti-freeze temperature
Setting range: -20 - +20 °C
Default value: 2 °C
start solar collector cooling
Setting range: 80 - 200 °C
Default value: 110 °C
start delta-T, stop delta-T: Here, you can set the temper-
ature difference between solar panel and solar tank at
which the circulation pump will start and stop.
max. tank temperature, max. solar collector temp.: Here,
you can set the maximum temperatures in the tank and
solar panel respectively at which the circulation pump
will stop. This is to protect against excess temperatures
in the solar tank.
max solar pool temperature: Here, you can set the
maximum temperature at which the solar panel stops
pool heating (if the installation is structured in this way).
Pool heating can only occur if there is a heat surplus
once the heating and/or hot water demand is met.
If the unit has an anti-freeze function and/or solar panel
cooling you can activate them here. When the function
has been activated, you can make settings for them.
freeze protection
anti-freeze temperature: Here, you can set the temper-
ature in the solar panel at which the circulation pump is
to start to prevent freezing.
NIBE VVM 310
solar panel cooling
start solar collector cooling: If the temperature in the
solar panel is higher than this setting, at the same time
as the temperature in the solar tank is higher than the
set maximum temperature, the external function for
cooling is activated.
See the accessory installation instructions for function
description.
MENU 5.3.7 - EXTERNAL ADDITION
Make settings for external addition here. External addi-
tion is for example external oil, gas or electric boiler.
If the external addition is not step controlled, in addition
to selecting when this should start also set the run time
for the addition.
If the external addition is step controlled you can select
when the addition is to start, set the maximum number
of permitted steps and whether binary stepping is to be
used.
If you select "prioritised additional heat" the heat is used
from the external addition instead of the heat pump.
See the accessory installation instructions for function
description.
MENU 5.3.11 - MODBUS
address
Factory setting: address 1
word swap
Factory setting: not activated
As from Modbus 40 version 10, the address can be set
between 1 - 247. Earlier versions have a fixed address
(address 1).
If you select "word swap", you will get "word swap" in-
stead of the preset standard "big endian".
See the accessory installation instructions for function
description.
Chapter 8 | Control - Menus
59