Four-time Frequency Mode
5-3-2. High Speed Count Range
The HSC's count range is: K-2,147,483,648 ~ K+2,147,483,647. If the count value exceeds
this range, up-flow or down-flow appears;
The up-flow means: the count value jumps from K+2,147,483,647 to be K-2,147,483,648
then continue to count; the up-flow means: the count value jumps from K-2,147,483,648 to be
K+2,147,483,647, then continue to count;
5-3-3.The Input Wiring Of HSC
For the input wiring of pulse, it differs according to PLC's model and counter's model. Below,
we show several typical wiring methods (take XC3-48 PLC as the example):
1
Increment Mode
5 Input Specifications and Wiring Methods