3. Interrupt function
Channel
Input
Rising interruption
CHL1
X2
I0000
CHL2
X5
I0100
CHL3
X10
I0200
4. Frequency measurement
The point is X1, X6, X7.
5. Pulse width modulation (PWM)
The point is Y0, Y1.
u T type: Y0, Y1 available
u R type: unavailable
6. Precise timer
32 bit precise timer, the timer range is T600 to T618, match with 10 interruption tag.

3-2 Soft component range

Soft
Name
component
X
Input point
Output
Y
point
Auxiliary
M
relay
S
Process
T
Timer
C
Counter
Pointer tag
Falling interruption
I0001
I0101
I0201
Range
X000~X017(octal)
Y000~Y017(octal)
M0~ M2999
0 M3000~M7999 0
M8000~M8767
S0~ S511
0 S512~M1023 0
T0~T99ÿ 100ms not accumulation
T100~T199ÿ 100ms accumulation
T200~T299ÿ 10ms not accumulation
T300~T399ÿ 10ms accumulation
T400~T499ÿ 1ms not accumulation
T500~T599ÿ 1ms accumulation
T600~T618ÿ 1ms with interruption precise time
T620~T639ÿ vacant
C0~C299ÿ 16 bits forth counter
Disable
interruption
instruction
M8050
M8051
M8052
Point
16
16
8000
768
1024
640
640

Advertisement