6.1.4

Read Time Setting

Read time setting sets the reading time of 1 reading operation. After trigger signal is on, or when the
readout command "Z" is sent, readout operation starts. If no data outputted within the specified time,
the readout operation stops.
Item
Read time setting
* When auto trigger with "Y0", read time is automatically set by the image processing.
The extended read time can be set with numerical parameters by inputting the command followed by a
4-digit numerical command in unit of 10 ms.
Item
Extended read time
numerical
setting
Example when read time 500ms)
<Esc>[DF7Q0Q0Q5Q0<CR>
0050 x 10 = 500 ms
*Setting is in unit of 10 ms.
NLV-5201 User's Manual
1st
Command
Trigger signal synchronization or "Z" "Y" command
Y0
control
Y1
1 second
Y2
2 seconds
Y3
3 seconds
Y4
4 seconds
Y5
5 seconds
Y6
6 seconds
Y7
7 seconds
Y8
8 seconds
Y9
9 seconds
YL
Read time infinite
YM
Read time 10 times
Command
[DF7
Qa
Qb
Qc
Description
Description
Setting of extended read time
Qd
(1000a+100b+10c+d)
[x10ms]
Chapter-6
Reading and Timing
Default
Default
(effective
range)
Synchronize
with trigger
70