[1]
F-1-13
9) Remove the tape from the machine.
10) Check to see if all accessories are contained in the
cardboard box that comes with the machine.
1.2.3 Installing the Scanner
iR5570 / iR6570
1) Open the ADF and eliminate the packaging
materials.
2) Remove the scanner screw [1].
[1]
F-1-14
Be sure to have the user keep the scanner screw since
it is used when the machine is moved.
1.2.4 Installing the Fixing
iR5570 / iR6570
1) Turn the fixing feeder assembly release lever [1] in
the direction of the arrow (left) to release the
transfer/separation corona assembly. Slide out the
fixing feeder unit [2] to the front.
0008-7942
2) Remove the separation claw release component [1]
and the tag [2] on the fixing feeder assembly.
Remove foreign matter, such as an adhesive of tape on
the feeder belt.
Assembly
[1]
F-1-15
Chapter 1
0008-7946
[2]
11