Pressure setting limits

The maximum setting pressure for the pressure limiting valves LS
pressure setting for shock valve PVLP. The maximum values recommended to avoid interaction can be
read in the following table.
The figures in the table have been calculated according to the following expressions:
PVLP ≤150 bar: LS
≤ 0.8 × P
A/B
PVLP >150 bar: P
- LS
PVLP
Max. pressure setting of LS
and LS
A
Pressure for PVLP
bar
[psi]
32
[460]
50
[725]
63
[914]
80
[1160]
100
[1450]
125
[1813]
140
[2031]
150
[2175]
160
[2320]
175
[2838]
190
[2755]
210
[3045]
230
[3335]
240
[3480]
250
[3625]
265
[3843]
280
[4061]
300
[4351]
320
[4641]
350
5075
380
5511
400
5801
PVLP
≥ 30 bar.
A/B
valves relative to PVLP shock valve
B
Max. for LS
A/B
bar
[psi]
-
-
40
[580]
50
[720]
64
[930]
80
[1160]
100
[1450]
112
[1625]
120
[1740]
130
[1885]
145
[2100]
160
[2320]
180
[2610]
200
[2900]
210
[3045]
220
[3190]
235
[3408]
250
[3625]
270
[3915]
290
[4205]
320
4641
350
5075
370
5366
or LS
depends on the chosen
A
B
Min. for LS
A/B
bar
[psi]
30 bar]
[435 psi]