4.8

Program button

Program button can be used/programmed in the appliance and
in the remote control.
Programming "Program" function
Each remote control program button can
be programmed with different temperature
values according with the user needs. A
temperature value can be programmed in
the remote control and another value in the
appliance.
Fig. 17
"Program" key
▶ Press buttons
be memorized.
▶ Press "Program" button for 3 seconds to save temperature.
The temperature is saved on "Program" when the LCD
panel stops blinking.
Using "Program" function
In order to select memorized temperature:
▶ Press "Program" key.
LCD shows pre-memorized temperature, which is now the
selected hot water temperature.
4.9

"Priority" function

PRIORITY is a function to prevents the user
from accidentally altering the water
temperature selected by another user.
Therm 6000S
Program
6720608920-32. 1 AL
and
to select temperature to
The appliance does not have a designated default priority.
Priority is attributed when the first user selects a temperature
(see chapter 4.4).
The following symbol appears for other users
The priority user may change the initial selection at any time.
Non-priority users cannot change the selection made by the
priority user.
The system resets priority function 5 minutes after last water
demand, returning to the initial state.
To select priority
Any user may select temperature selection priority in the
following manner:
▶ Press one of the selection keys
5 seconds.
Priority cannot be selected when the
appliance is working.

4.10 Purge the appliance

If there is a risk of freezing, proceed as follows:
▶ Close the cold water valve of the water heater.
▶ Open hot water taps to drain the water heater.
▶ Remove all the water contained inside of the appliance.
CAUTION:
▶ The non accomplishment of the
purgative of the appliance whenever the
freezing risk exists, it can damage
components of the appliance.
The internal frost protection is designed to
provide protection for the water heater
down to approximately -10 °C for short term
conditions only. It will not protect the
appliance in areas where the temperature is
frequently expected to be below freezing.
The frost protection will not protect the
installation outside the appliance from
freezing. Suitable measures should be taken
to protect the installation against frost
damage.