26 | Installation instructions
▶ Press and hold "Program" button and press ON/OFF button
to turn appliance ON (Fig. 42).
Fig. 42
Gas tunning mode
▶ As soon as '188' is displayed, release "Program" button
, and the display reads P2.
▶ Press
or
until P1 appears.
+
NOTE: While in this mode the appliance will
run constantly at maximum power and allow
maximum water flow.
For inlet gas pressure adjustment see values in Table 8 :
Gas type
GN
kPa
2,0
Table 8
▶ Turn on high volume of hot water flow (at least 15 l/m) and
burner will light. If heater display reverts to P2, open more
hot water fixtures to allow sufficient flow. Press
P1 reappears on the display.
▶ Operate all other gas appliances on same gas piping system
at maximum output.
▶ Record lowest operating gas pressure reading in Table 7 .
Gas pressures lower than 2,0 kPa for Natural Gas or 3,0
kPa for Butane will result in insufficient degree rise to the
hot water being used, reduced hot water volume, possible
error code faults and must be corrected.
Check gas pipes dimensions.
8.3
Adjusting CO
(carbon dioxide)
2
The CO2 can only be adjusted by a certified
gas technician with a calibrated CO
analyser.
6 720 800 095 (2015/11)
When the gas pressure is correct:
▶ Press ON/OFF button to turn off the appliance.
▶ Remove plastic screw on the exhaust collar as seen in
Fig. 43.
6720608920-18. 1 AL
Fig. 43
▶ Insert CO
of the probe should be in the center of the flue pipe (approx
Butane
40mm inserted). Avoid air gaps between probe and
measuring port as they can alter readings.
3,0
▶ While holding the Program (P) button, press the ON/OFF
button to turn ON the heater (see Fig. 44).
until
+
Fig. 44
▶ While holding the Program
button to turn ON the heater. As soon as '188' flashes on
the display, release the Program button. The display should
2
now read P2.
▶ Press
CAUTION:
One factor that may affect CO
improper gas pressure.
▶ Check and adjust gas pressure, see
chapter 8.2.
Measuring port
analyser probe into the measuring port. The tip
2
P
button, press the ON/OFF
+
or
button until "P1" appears on display.
levels is
2
Therm 6000S