Þ CONFIGURATION
Water press.
Group temp.
T stop steam
MEASUREMENT UNITS
N° ground
Piston diamet.
SOFTNER REGENER.
Water pressure – indicates the boiler pressure: 1.3 ÷ 1.4 bar
(18 ÷ 20 psi)
Unit temperature – indicates the unit temperature, from 70 to
110 ° C and from 158 to 230 ° F
Stop steam temperature – indicates the automatic stop steam
temperature (Turbosteam). Can be set between a minimum of 50
and a maximum of 85° C (122 – 185 ° F).
MEASURING UNIT – includes 2 sub-menus
Temperature – can be set to °C Celsius centigrade or °F Fahrenheit
degrees.
Pressure – can be set to bar or psi.
N. grounds – refers to number of grounds, from 0 (external
container) to 50.
Piston diameter – various piston diameters can be set. “001” =
Ø 35mm; “002” = Ø 44 mm; “003” = Ø 50 mm.
REGENERATION - includes the parameters for the softner
regeneration: liters of resin (da 0,1l a 25l), hardness (da 0 a 45 °F)
Þ CONFIGURATION
Custumer prog.
Paym. system
WASHING OPTIONS
Standard data
Archive reset
DATA IN/OUT
MAINTENANCE
Customer programming – YES/ NO
Payment system – permits configuration of payment system,
when connected.
WASHING OPTIONS
Includes 2 parameters for configuring automatic washing (10’ ÷
99’ OFF) and milk block (YES – NO)
Standard data – loads standard data. YES/NO
Archive reset – zeros the error log stored on the machine: YES/
NO
DATA IN/OUT – contains three entries:
Key – indicates the key number from 0 to 60.
Data IN transfer from smart card to machine. OUT transfer from
machine to smart card.
TX/RX – to start data transfer

6. Configuration menu

MANUTENZIONE - comprende 5 parametri per l'impostazione dei
parametri di manutenzione:
1,4 bar
070°C
075°C
030
002
u
+
HARDWARE SETUP - Includes 5 entries for setting power and voltage
parameters for the motor (disabled):
NO
OFF
Current threshold – maximum current setting for coffee pressing.
There is just one parameter for the whole machine, from 001 to 009.
NO
Recommended setting: 005.
NO
PWM threshold – maximum motor voltage for the rise phase. It is a
u
fixed setting and there is just one parameter for the whole machine,
+
from 001 to 255. Recommended setting: 240.
PWM compression – voltage applied to the motor for the return of
the chamber after compression. It is a fixed setting and there is just
one parameter for the whole machine, from 001 to 244. Recommended
setting: 140.
Compensation current: power supplied to the motor during
dispensing to prevent return of the unit (reversibility), from 00 to 09.
Recommended setting: 06.
Washing threshold – maximum current allowed for the motor during
the washing phase.
Max cycles - the number of cycles initially set: 40,000.
Max days - the number of days initially set: 185.
N° cycles - the number of cycles remaining before the next
maintenance session.
N° days -
the number of days remaining before the next
maintenance session.
Reset -
options are:
NO, countdown of cycles and days remaining
before the next maintenance session.
ON, the settings for number of cycles (40,000)
and remaining days (185) are reset
OFF, all controls for programmed maintenance
are disabled, and the “N. cycles” and “N. days”
counters are zeroed.