English
MALFUN.
DESCRIPTION
CODE
Timeout unit wash cycle
094
(24h)
Timeout milk circuit wash
095
cycle (24h)
Malfunction archive reset
098
099
Default data input
Not working machine, with
display extinguished
Machine
with
solenoid valves and group not
working
15. Defects - Malfunctions
POSSIBLE CAUSES
A unit wash cycle was not
performed within 60 minutes
of the message.
A milk circuit wash cycle was
not performed within 60
minutes of the message
A malfunction archive reset
has been executed
display
ON;
SOLUTIONS
- Control the feeding presence in the electrical net
s y s t e m
- If there is power:
1 Open the machine
2 Check the feeding presence in the main electrical
terminal CT and in the transformer TR
- If theres power:
- Check the power (10÷11Vac) on 1-5 pins of the Y13
CPU board connector
- check the LED on the CPU board:
- if at the end of all the controls the display it remains
extinguished, replace CPU board
- If theres no power:
- check: power supply cable, main switch, cable
- if at the end of all the controls the display it remains
extinguished, replace TR transformer
1 Open the machine
2 Check the power (23÷25Vac) on 2-4 pins of the Y13
CPU board connector
- If theres power:
- replace CPU board
- If theres no power:
- replace TR transformer
English
DL1 red = OFF
DL3 green = Lam
DL4 red = OFF