How to enter “Programming” menu: Insert the smart card.
Besides the date and hour, the word TECHNICIAN will appear.
14 January
wednesday
Technician
Display of available menus: Press the PRG (29) key.
Þ TECHNICAL PROG.
KEY MENU
CONFIGURATION
TESTING
WEIGHTING
Access to menus: Use the “+” (30) and “-“ (31) keys to position
the cursor on the desired line, then press the PRG (29) key.
Press one of the coffee dispensing keys (32) (the relative led will
remain on, not flashing). The following message will appear on the
display:
Þ KEY MENU
Type
Water dose
MSX cof, dose
MDX cof, dose
Backing
Infusion
Prs. discharged

4. Programming

2004
15:15:04
u
+

5. Key menu - Coffee selection

1 coffee
090
043
000
00.2
u
00.3
+
00.5
Access and modification of sub-menus: Use the “+” (30) and “-
“ (31) keys to position the cursor on the desired line, then press the
PRG (29) key.
Use the “+” (30) and “-“ (31) keys also to modify the message or
number, then press the RES (24) key to confirm the data.
Note: When modifying data, the cursor changes from “
Þ KEY MENU
Type
Water dose
MSX cof, dose
MDX cof, dose
Backing
Infusion
Prs. discharged
Exiting the programming menu: Always press the RES (24)
key to confirm/exit the menu.
Þ KEY MENU
à
Type
Water dose
MSX cof, dose
MDX cof, dose
Backing
Infusion
Prs. discharged
The following coffee selection parameters can be modified:
- type (key personalizing, e.g.: 1 coffee, 1 cappuccino, 2 coffee,
2 cappuccini, fast washing, stop, null);
- water dose (volumetric dosage pulses, from 0 to 999, with
increments of 1);
- MSx dose coffee (left grinde encoder pulses, 0 ÷ 200 with
increments of 1);
- MDx dose coffee (right grinde encoder pulses, 0 ÷ 200 with
increments of 1);
- backing (the return time for the chamber, which can be adjusted
for each key: from 0 to 6 with increments of 0.1 seconds);
- infusion (infusion time: 0 ÷ 6 seconds, with increments of 0.1);
- pressure release (pressure release time: 0 ÷ 5 seconds, with
increments of 0.1)
- drying (pod drying time; 0 ÷ 5 seconds, with increments of 0.1).
Note: the coffee doses for both grinders set in the technical
programming menu, are subject to change in the customer
programming menu within a range of + 10 of the set value.
English
n
"à".
” to
1 coffee
090
043
000
00.2
u
00.3
+
00.5
1 coffee
090
043
+
-
000
u
00.2
00.3
00.5