Please Wait; Configuration Menu - La Cimbali M200 Engineer's Manual

Table of Contents

Advertisement

2.6 "Copy group" function
This feature allows you to copy the selected coffee group settings for all other machine units.
 TECHNICAL PROG.
KEY MENU
SELF LEARNING
Copy unit
CONFIGURATION
DATA MENU
Operate as follows:
1) position the cursor over "Copy group" using the
and
keys and press the
2) set the group to be copied to the other machine groups by
using the
and
keys and confirm by pressing "OK" key.

2.7 Configuration Menu

 CONFIGURATION
Boiler
Boiler pr.
BOILER
Level sensitivity
UNIT OF MEASUREMENT
Boiler- The heating element and the self-leveller feature
of the boiler are activated or deactivated with the "Boiler"
ON/OFF function.
Boiler Pressure- indicates the pressure of the boiler;
0.6–1.6 bar (9–23 psi).
BOILER - this parameter includes the entries for setting the
temperature of the boilers, values that can be set are 60 to
110°C (140 to 230°F) in steps of 0.5°C. In this menu there
is the possibility of programming a temperature offset for
the boilers, adjustable in a range of +/- 2°C. The standard
setting is the current value of +1.5°C.
Level Sensitivity - indicates the degree of sensitivity of
the level probe, which then operates the filling of the boiler
with water. For safety reasons, automatic level control of
the self-leveller service-boiler is disabled when the service-
boiler heating element is turned off.
- Note: set a value of 1 if the machine is installed with very
conductive water.
Set a value of 3 if the water used is not very conductive
(very soft).
UNIT OF MEASUREMENT - Includes 2 sub-menus:
temperature - can be set to: °C, centigrade - Celsius or
°F, Fahrenheit.
pressure - can be set to bar or psi.
+ 
3
key;
ON
+ 
1.3 bar
2

PLEASE WAIT

3) at the end of the process, all the units will have the
same parameters.
Time control
shows dispensing time on display: YES/
-
NO (from 1 sec to 1 hour).
Buzzer - enables/disables all acoustic signals when keys
are pressed or messages are displayed: YES/NO.
Flush - Adjusts the duration of the FLUSH function,
adjustable between 0 and 3 seconds.
Low power - YES/NO
WASHING OPTIONS - - Allows the user to select the run
time and block time for the "Wash" and "Water change"
functions.
Customer programming - Customer programming: YES/
NO.
By activating the function (YES), it is possible to provide
the user with additional functions:
- change the cup warmer level (but not the level settings)
- turn the coffee boiler on/off.
- activate energy saving mode.
Programming lock - Lock programming lock: YES/
NO. By activating the function (YES), all the keys on the
programming keypad are locked, including the cup-warmer
key. The only actions permitted are the key sequence for
technical access, pressing the arrow key
softener regeneration and message removal.
Drying - Varies drying time from 0 to 5 with intervals of 0.1
seconds "if Drying kit is present".
50 EN
1
2
to perform

Hide quick links:

Advertisement