Nortel DMS-100 Series General Description Manual page 96

Ringing system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

3-28 Ringing in Series II peripherals
Procedure 3-1 Dual LCM ringing generator configuration change procedure
At the MAP terminal
1
2
3
4
5
6
297-1001-131 Standard 06.01 October 2000
To access table LCMINV, type
> TABLE LCMINV
and press the Enter key.
To position on the tuple for the first LCM, type
> POS HOST 0 0
and press the Enter key.
Example of a MAP display:
>POS HOST 0 0
HOST
00 0
LCE
N
3 256K 256K
LCM Y
F REA
For more information about ringing types, refer to chapter "DMS-100 ringing
overview" in this document and the Customer Data Schema Reference
Manual .
Check the RNGTYPE for the LCM. The previous example shows a
RNGTYPE of frequency selective.
To check the RNGTYPE for the other LCM in the LCE frame, type
> POS HOST 0 1
and press the Enter key.
Example of a MAP display:
>POS HOST 0 1
HOST
00 1
LCE
N
8 256K 256K
LCM Y
F REA
To quit the table, type
> QUIT ALL
and press the Enter key.
To access the PM level of the MAP terminal, type
> MAPCI;MTC;PM
and press the Enter key.
Example of a MAP display:
PM
4
1
P
29 6X04AA XLCM11BD
20
30
40
50 HLCM
RNGTYPE is set to frequency selective (F).
38
1
P
29 6X04AA XLCM11BD
20
30
40
50 HLCM
RNGTYPE is set to frequency selective (F).
SysB
ManB
OffL
0
0
0
LTC
(16)(18)(17)(19)$
LTC
(0)(2)(1)(3)$
CBsy
ISTb
InSv
0
3
39
0
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dms-100