Figure 3-9 Summary of Dual LCM ringing generator configuration change procedure
Check the
configurationin
table LCMINV
Post the LCM
units
Do you need
to switch RGs
to the RG you
do not want to
power down?
Y Y
Use SWRG to
get both units on
the correct RG
N N
Busy the LCM
units
Perform
changes to the
RG
Change the
RNGTYPE to
unassigned in
table LCMINV
Perform a
NILCHANGE on
the other LCM
Ringing in Series II peripherals 3-27
This flowchart provides a
summary of the procedure.
Use the instructions in the
step-action procedure that
follows this flowchart to
perform the procedure.
Change the original
tuple to the desired
RNGTYPE
Perform a
NILCHANGE on
the other LCM
Post and RTS
the LCM units
TST the LCM
units
Repeat this
procedure for
the other RG
You completed
this procedure