Nortel DMS-100 Series General Description Manual page 110

Ringing system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

3-42 Ringing in Series II peripherals
12
At the MAP terminal
13
14
15
16
17
297-1001-131 Standard 06.01 October 2000
Reseat RG-1 and restore power.
To quit the PM level of the MAP terminal, type
> QUIT ALL
and press the Enter key.
To access table LCMINV, type
> TABLE LCMINV
and press the Enter key.
Example of a MAP responce:
CI:
TABLE: LCMINV
To postion on the tuple for the LCM, type
> POS RLCM 0 0
and press the Enter key.
To change the ringing scheme, type
> CHA LCMTYPE
and press the Enter key.
Example of a MAP responce:
ENTER Y TO CONTINUE PROCESSING OR N TO QUIT
Enter Y to continue processing the change request and press the Enter key.
Example of a MAP responce:
LCMTYPESEL: LCM
Press the Enter key to leave this entry as it is.
Example of a MAP responce:
RGEQUIP: Y
Press the Enter key to leave this entry as it is.
Example of a MAP responce:
RNGTYPE: F
Enter UNASSIGNED and press the Enter key.
Press Enter when the system prompts you to change the value of other fields
in the tuple. This avoids making any other changes. The system will prompt
you to verify the change. See the following MAP response.
Example of a MAP response:
TUPLE TO BE CHANGED:
RLCM
00 0
RLCM
N
3 256K 256K
LCM Y UNASSIGNED RLCM
ENTER Y TO CONFIRM, N TO REJECT OR E TO EDIT.
Enter Y to confirm the tuple change request and press the Enter key.
Repeat steps 15 and 16, but enter the desired value in field RNGTYPE
instead of UNASSIGNED.
4
1
B
26 6X04AA XLCM04AH
(0)(2)(1)(3)$ N Y N 6X50AA
LTC
1