Nortel DMS-100 Series General Description Manual page 108

Ringing system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

3-40 Ringing in Series II peripherals
7
8
9
297-1001-131 Standard 06.01 October 2000
PM
LCM
LCM
RLCM 00 0
InSv
Unit0:
InSv
Unit1:
InSv
Drwr:
01
23
45
67
..
..
..
..
Both units use ringing generator 0 (RG-0).
Are the units in the LCM aligned to use RG-0?
If both LCM units
are aligned and both use RG-0
are not aligned or both do not
use RG-0
To get an LCM unit to use RG-0, type
> SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the unit number you want to switch to RG-0 (0 or 1)
Example of a MAP responce:
swrg unit 1
LCM RLCM 00 0 Unit 1 SWRG Passed
Note: Perform this step for each LCM unit that needs to use RG-0.
To busy unit 1 of the LCM, type
> BSY UNIT 1
and press the Enter key.
SysB
ManB
OffL
0
0
0
0
0
0
Links_OOS: CSide
/RG: 0
/RG: 0
11
11
11
11
89
10
23
45
67
..
..
..
..
..
Do
Step 9
Step 8
CBsy
ISTb
InSv
0
3
18
0
1
0
0 , PSide
0
11
RG: Pref 0 InSv
89
Stby 1 InSv
..