Using Controls

A remote control receiver and remote controller
(see Figure 60) allow the dust collector to be
turned ON and OFF from up to 75 feet away, pro-
viding that direct line-of-sight is maintained.
The Model G0777/G0777HEP is equipped with a
circuit breaker/thermal overload button. If the dust
collector experiences an overload, this button
pops out and the machine shuts down.
To restart the machine, you must first fix the cause
of the overload, press the circuit breaker/thermal
overload button, then turn the power switch OFF,
then ON to reset the thermal overload.
Remote
Controller
Power
Switch
Figure 60. Remote control receiver and
handheld features.
-38-
To prevent accidental startups by other common
RF items like garage door openers, the remote
control signal for the Model G0777/G0777HEP is
IR (infrared) rather than a RF (radio frequency)
signal. The remote control switch features a fac-
tory-set 256-code channel setting, which prevents
the simultaneous startup of two G0777's.
Operating Remote Controller
Refer to Figure 61 and the following descriptions
to understand the remote control functions.
Remote
Receiver
Circuit
Breaker/
Thermal
Overload
A. TIME Button: Selects auto shut-down time.
B. START/STOP Button: Turns the dust collec-
C. SET Button: Used to reprogram receiver.
A
B
C
Figure 61. Remote controls.
By pressing TIME Button once, dust col-
lector will run for 1 hour; 1H illuminates on
Timer Indicator on control panel. Consecutive
pushes increase operation time in 1, 2, 4 or 8
hour intervals—up to 15 hours. The machine
will stop once set time period ends. To can-
cel timer before set time has elapsed, turn
POWER Switch OFF or press START/STOP
button on remote controller.