18. Install rubber drum seal over top lip of drum
rim. Pay special attention to orientation of
seal shown in inset (see Figure 32).
Figure 32. Installing canister seal.
19. Place dust collection bag into collection drum,
as shown in Figure 33.
Figure 33. Bag installation.
-26-
Seal
Drum
Rim
21. Connect 1" hose and 5" hose to collection
drum (see Figure 34).
22. Connect other ends of both hoses to cyclone
housing (see Figure 34), and secure them in
place with appropriate diameter hose clamps.
23. Install filter dust bag (see Figure 34) to filter
and clamp it in place using spring clamp.
Tip: To make filter element bag installation
easier, use a piece of tape to hold bag in
place while you position spring clamp and
tighten it.
24. Ground wire is pre-installed on drum lid.
Remove one mounting bolt from frame, slide
wire terminal onto bolt, then re-install bolt in
frame (see Figure 34).
Spring
Clamp
Dust
Bag
1" Hose
Figure 34. Hoses and filter dust bag installed.
20. Place drum lid onto drum and tighten latches,
then roll drum under cyclone port so drum
spout faces dust collector, (see Figure 35).
Drum
Lid
Drum
Spout
Figure 35. Collection drum positioning.
Model G0777/G0777HEP (Mfd. Since 04/19)
Attach Ground
Wire Here