TROUBLESHOOTING

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors
can cause improper and dangerous operation. Verify proper operation after servicing.
ATTENTION: Lors des opérations d'entretien des commandes, étiqueter tous les fils avant de
les déconnecter. Toute erreur de câblage peut être une source de danger et de panne.
If any of the following symptoms occur on this washer, check the suggested remedies
listed below. If all probable causes have been eliminated and the symptom still exists,
contact your local Dexter agent for further troubleshooting assistance. See contact
information at the end of this manual. Parts & Service Manuals from Dexter are also
available for further troubleshooting assistance.
Probable
Symptom
Cause
Machine does
Power Supply
not start
Door Switch
Fuses or circuit
breaker
Control
Transformer
Check PCB
boards
Check wiring
between PCB
and VFD
Check Door
Lock
Mechanism
Door does not
Check display
lock
for message
Door locking
mechanism
Door Switch
8514-290-001 REV B page 37
Suggested Remedy
Check these areas: Circuit breakers,
Voltage, Power leads, Power connections. Is
front display lit?
Check for continuity through door switch
when door is closed. If no continuity, adjust
or replace door switch.
Check the 1.5 amp and 2.0 amp fuses (60
hz models) or circuit breaker (50 hz models)
for continuity. If no continuity, replace fuse
or breaker.
Check voltage output from control
transformer for 24 VAC and 120VAC (50 hz
models have 24 VAC only). If voltage is
incorrect, check for proper transformer tap
connection or replace transformer.
Check all wire connections for sure contacts.
Check data cable phone type connectors:
unplug and replug with power removed.
Check that 120 VAC power (for 60 hz) or 24
VAC power (for 50 hz) is at door lock motor
after start button is pressed.
Follow tests described in fault code section.
Check to ensure that mechanism is
receiving 120VAC for 60 hz models (or
24VAC for 50 hz models) from main relay
PCB. If it is receiving power but not
functioning, then replace mechanism.
Check for continuity through door latch