MODEL JUMPER/ DRIVE SIZE
Condition
Action
Exit
MODEL JUMPER/ DRIVE PARAMETER
Condition
Action
Exit
NON-DEXTER DRIVE
Condition
Action
Exit
8514-290-001 REV B page 32
machine control checks for this condition when power is cycled
and before starting every machine cycle.
The machine will not start and the Error Code will continue to be
displayed until the condition no longer exists and the prompt is
followed to Reset the Error Code and return the Machine to Idle
Mode.
This error occurs when the jumper connections to Ground (Pin 7)
on the Model Jumper Header do not match the VFD size code.
When detected, the control turns off the motor and all relays.
There is no delay in the action once the criteria are met. The
machine control checks for this condition when power is cycled
and before starting every machine cycle.
The machine will not start and the Error Code will continue to be
displayed until the condition no longer exists and the prompt is
followed to Reset the Error Code and return the Machine to Idle
Mode.
This error occurs when the jumper connections to Ground (Pin 7)
on the Model Jumper Header do not match the VFD parameters
being used.
When detected, the control turns off the motor and all relays.
There is no delay in the action once the criteria are met. The
machine control checks for this condition when power is cycled
and before starting every machine cycle.
The machine will not start and the Error Code will continue to be
displayed until the condition no longer exists and the prompt is
followed to Reset the Error Code and return the Machine to Idle
Mode.
This error occurs when a non-Dexter VFD is installed in the
machine.
When detected, the control turns off the motor and all relays.
There is no delay in the action once the criteria are met. The
machine control checks for this condition when power is cycled
and before starting every machine cycle.
The machine will not start and the Error Code will continue to be
displayed until the condition no longer exists and the prompt is
followed to Reset the Error Code and return the Machine to Idle