Dexter Laundry T-350 Operator's Manual page 29

Industrial washers. express on-premise o-series control
Table of Contents

Advertisement

Exit
TEMP SENSOR SHORT
Condition
Action
Exit
Note
TEMP SENSOR OPEN
Condition
Action
Exit
Note
NO HEAT RISE
Condition
Action
8514-290-001 REV B page 29
There is no delay in the action once the criteria are met.
The machine will not start and the Error Code will continue to be
displayed until the condition is no longer present. Once the
condition is removed, the machine still will not start and the Error
Code will continue to be displayed until the prompt is followed to
Reset the Error and return the machine to Idle Mode.
This error occurs when the control detects a short circuit from the
temperature sensor.
When detected, the control turns off the motor and all relays.
There is no delay in the action once the criteria are met.
The machine will not start and the Error Code will continue to be
displayed until the condition is no longer present. Once the
condition is removed, the machine still will not start and the Error
Code will continue to be displayed until the prompt is followed to
Reset the Error and return the machine to Idle Mode.
This error code is disabled if the washer model does not have a
temperature sensor
This error occurs when the control detects an open circuit from
the temperature sensor.
When detected, the control turns off the motor and all relays.
There is no delay in the action once the criteria are met.
The machine will not start and the Error Code will continue to be
displayed until the condition is no longer present. Once the
condition is removed, the machine still will not start and the Error
Code will continue to be displayed until the prompt is followed to
Reset the Error and return the machine to Idle Mode.
This error code is disabled if the washer model does not have a
temperature sensor
This error occurs when the control detects that the temperature is
not increasing.
When detected there is a delay of 15 minutes before the error is
active. Once active, the control will display the "NO HEAT RISE"
prompt, alternating with the normal Cycle Progress screen at a
rate of 5 seconds on, 5 seconds off. The heating relay will also be
turned off. Otherwise the cycle will continue normally.