Setting Up A Rosemount 2460 System Hub; Introduction; Installation Procedure - Emerson Rosemount 2460 System Hub Reference Manual

For tank gauging systems
Hide thumbs Also See for Rosemount 2460 System Hub:
Table of Contents

Advertisement

Configuration
October 2018
4.3

Setting up a Rosemount 2460 System Hub

4.3.1

Introduction

A Rosemount 2460 System Hub is easy to install and configure by using the TankMaster Winsetup
configuration program. The WinSetup installation wizard guides you through the basic configuration to
start up a Rosemount 2460.
Host communication via the Ethernet 1 port (ETH1) and Modbus TCP protocol can be setup by using the
Web based Graphical User Interface (GUI). See
information.
4.3.2

Installation procedure

Installation of a Rosemount 2460 System Hub in a Rosemount Tank Gauging system includes the
following basic steps:
1. Ensure that a plan is available for all tanks and devices with tag names, communication addresses,
number of temperature elements and other data that is needed for a system setup.
2. In case devices from other vendors will be connected to the field ports, ensure that appropriate
modem cards are installed which support the communication protocols. Also, check that the 2460
firmware supports the modem cards and protocols, see
TankMaster 6.C0 and higher is required for configuration of 2460 with Enraf
Appendix A: Specifications and Reference Data
protocols. See also
3. Make sure that the Rosemount 2460 is properly wired and up and running. Check that the Power LED
is on and the Status LED indicates normal operation (see
4. (Redundancy). Make sure that the two system hubs are properly wired as described in
page
supported by TankMaster 6.D0 and higher versions.
5. Ensure that the TankMaster WinSetup configuration program is up and running.
6. In WinSetup, setup the appropriate protocol channel
that communication between the TankMaster PC and the Rosemount 2460 is established.
7. In TankMaster WinSetup, start the device installation wizard and configure the system hub as
described in
a. Specify device type (2460) and name tag.
b. Check that the correct communication channel is enabled and verify communication with the
c. Verify that the Host ports and Field ports are using the right protocols for communication with
d. Configure the tank database. See configuration examples that illustrate how the tank databases
1.
See Section 5 in the
Rosemount System Configuration Manual
munication protocol channels.
50
"Exchanging a modem card" on page
32. See also
Figure 3-16 on page
"Installation wizard" on page
TankMaster host computer.
TankMaster work stations or other host systems, and with field devices such as the Rosemount
2410 Tank Hub and the Rosemount 5900S Radar Level Gauge.
of the Rosemount 2460 and the Rosemount 2410 are related to each other in
the Rosemount 2460 System Hub and the Rosemount 2410 Tank Hub" on page
Configuration of Enraf devices is covered by section
Configuration of Whessoe WM550/660 devices is described in
on page
181.
Section 6: Service and Troubleshooting
for information on supported electrical interfaces and
45. Note that configuration of redundant Rosemount 2460 is
(1)
in the TankMaster host PC. This step will ensure
55:
(Document no. 00809-0300-5100) for more information on how to configure com-
Reference Manual
00809-0100-2460, Rev DE
Table 3-1 on page 23
for more information.
®
support. See
108.
Table 5-3 on page
94).
"Enraf® Device Configuration" on page
"Whessoe Device Configuration"
for more
"Wiring" on
"Tank databases of
70.
171.
Configuration

Advertisement

Table of Contents
loading

Table of Contents