o Advanced Network
• HTTP Port: Specify the port the web server will be accessed on. If the port is
changed from the default value of 80, the AR may be accessed by specifying the
new port number in this format: http://IPADDRESS:NEWPORT. Example:
Navigate to http://192.168.1.254:8000 for an IP address of
192.168.1.254 on port 8000.
• Linkback URL: This setting allows control of the hotlink displayed on the
Goodbye page. It allows use of the public IP address or DNS name instead of the
internal IP address of the AR, which is the default setting. If this setting is left
blank, the hotlink will be the IP address of the unit. Enter up to 128 characters.
• Telnet Port: Specify the port to use for telnet access (default 23). DxP Port:
Specify the port to use for DxP protocol (default 9100).
• Time Setup: Setup of the time server is required for Scheduling and Logging
functions.
o Enable: Enable or disable the use of the time server.
o Time Server: Specify the time server. The default is time.nist.gov.
o Time Zone: Specify the time zone (-12 to +12) relative to GMT.
o DST Enable: Enable or disable the use of Daylight Savings Time.
o DST Start/Stop: Specify the start and stop times for DST.