FAAC 455 D Installation Manual
FAAC 455 D Installation Manual

FAAC 455 D Installation Manual

Operator and control panel
Hide thumbs Also See for 455 D:

Advertisement

T
4 0 0 O
H E
4 5 5 D C
I
N S T A L L A T I O N
Logic Tables of 455 D Control Panel
Maintenance
Safety in Gate Design
P E R A T O R A N D
O N T R O L
M
CONTENTS
P
:
A N E L
A N U A L
2
4
5
6
6
6
7
7
10
12
13
14
14
14
15
15
16
18
20
22
22
22
23
24
26
26
27
28
November, 2003
400 Operator And
455 D Control Pa nel
Installation Manual
FAAC International, Inc.
303 Lexington Avenue
Cheyenne, WY 82007
www.faacusa.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 455 D and is the answer not in the manual?

Questions and answers

Summary of Contents for FAAC 455 D

  • Page 1: Table Of Contents

    Install the Operator Install the 455 D Control Panel Exploded View, 400 CBC 400 Parts List The 455 D Control Panel General Description Installing the 455 D Control Panel Connect the Main Power Supply Connect the Operator to the Control Panel Check the Motor’s Direction of Rotation...
  • Page 2: Important Safety Information

    November, 2003 400 Operator And Page 2 455 D Control Pa nel Installation Manual MPORTANT AFETY NFORMATION Both the installer and the owner and/or operator of this 3. Your gate must be properly installed and must work system need to read and understand this installation...
  • Page 3 November, 2003 400 Operat or And P a ge 3 455 D Control Pa nel Installation Manual 1. Use this equipment only in the capacity for which it 4. Do not attempt to impede the movement of the was designed. Any use other than that stated should gate.
  • Page 4: Technical Data

    November, 2003 400 Operator And P age 4 455 D Control Pa nel Installation Manual ECHNICAL 400 Model Parameter Standard High Speed Slow Speed Long CBCR Model CBAR CBAC CBAC CBACR Apartment, subdivision, industrial, and commercial applications Duty type 80 Cycles/ Hour Duty cycle 12 (3.6)
  • Page 5: Unpacking The Operator

    November, 2003 400 Operat or And P a ge 5 455 D Control Pa nel Installation Manual NPACKING THE PERATOR 1 400 Operator - 1 each When you receive your 400 Operator, complete the following steps. 2 Protective Cover - 1 each...
  • Page 6: The 400 Compact Operator General Characteristics

    212 deg F (100 deg C). Also for the protection and proper operation of the 400 Operator, each gate The FAAC 400 Operator is an automatic gate operator leaf on which it is installed must have a fixed positive for a swinging gate leaf.
  • Page 7: Manual Release Mechanism

    November, 2003 400 Operat or And P a ge 7 455 D Control Pa nel Installation Manual NSTALLING THE PERATOR Installing the 400 operator consists of the following steps: 1. Attach the rear mounting bracket 2. Attach the mounting hardware 3.
  • Page 8 November, 2003 400 Operator And P age 8 455 D Control Pa nel Installation Manual Insert the rear fork (hex cut up if you have a nylon rear push the piston in completely and pull back out fork) into the rear flange of the operator. Secure with approximately ¼”...
  • Page 9 November, 2003 400 Operat or And P a ge 9 455 D Control Pa nel Installation Manual Dimensions, In. (cm) 400 Standard, high speed, and slow speed models 5 (13) 5 (13) (70) 9/16 No Limit Must be less than A Figure 5.
  • Page 10: Install The 455 D Control Panel

    • Connecting the main power to the control meets all applicable electrical codes. panel For the complete 455 D Control Panel Installation Instructions, see pages 14—25 of this manual. Figure 7. The layout of a sample gate system Locate switches at least...
  • Page 11 November, 2003 400 Operat or And P a ge 1 1 455 D Control Pa nel Installation Manual Figure 8. Install the locking cap cover LEED THE PERATOR Air bubbles in hydraulic fluid cause erratic performance in a hydraulic system, so you must rid the 400 Operator of that air to insure smooth operation.
  • Page 12: Exploded View, 400 Cbc

    November, 2003 400 Operator And P a ge 1 2 455 D Control Pa nel Installation Manual , 400 CBAC XPLODED...
  • Page 13: 400 Parts List

    November, 2003 400 Operat or And P a ge 1 3 455 D Control Pa nel Installation Manual 400 P ARTS PART NO. DESCRIPTION PART NO. DESCRIPTION 7119405 Protective Cover End Cap Plug 2036 Galvanized Nut (8mm) 7019195 Tie-Rod (Protective Cover)
  • Page 14: The 455 D Control Panel General Description

    ESCRIPTION all applicable electrical codes. The installer should refer to the installation manual for a given operator for more The FAAC 455 D control panel is used to operate the information. following models. : An installation is U.L. compliant only...
  • Page 15: Connect The Operator To The Control Panel

    November, 2003 400 Operat or And P a ge 1 5 455 D Control Pa nel Installation Manual connect the white wire to terminal 4 (on the J4 ONTROL ANEL terminal strip), the black wire to 5, the red wire to 6.
  • Page 16: Connect Other Devices

    24 VDC accessories. Disengage the operator(s) with the Manual Release key (see operator installation manual), and open the : The 455 D control panel allows a gate by hand about halfway. maximum accessory load of 800 mA.
  • Page 17 (N.O.) contacts. Connect such devices to operator(s) terminals 9 and 14. : The FAAC radio receiver plugs into the 5 prongs labeled J2 (Quick connect port). Page 19 shows how to connect a three or four wire OP_A...
  • Page 18: Set Other Operating Controls

    OGIC opening and flashes during closing. WARNING! Turn the main power off before you make any electrical connections. For all FAAC hydraulic operators using the 455 D THER PERATING ONTROLS control panel, the force must be set at its maximum...
  • Page 19 Saf ety Loop Detector Additional (f or closing) Reversing Devices FAAC PHOTO-BEAMS LOOP DETECTOR (FAAC) NO = Normally Open, NC = Normally Closed, C = Common, TX = Transmitter, RX = Receiver Figure 13. Common Accessories wired to 455 D Control Panel...
  • Page 20: Programming

    November, 2003 400 Operator And P a ge 2 0 455 D Control Pa nel Installation Manual ROGRAMMING BASIC PROGRAMMING program automated system, “Programming Mode” must be accessed. Programming is split into two parts: BASIC and ADVANCED. Display Function Default...
  • Page 21 November, 2003 400 Operat or And P a ge 2 1 455 D Control Pa nel Installation Manual ADVANCED PROGRAMMING Display Function Default NDICATOR ICHT If 0 is selected, the output functions as a standard indicator-light (lighted at opening and pause, flashing at closing, and off when gate closed).
  • Page 22: Learning Of Operating Times

    November, 2003 400 Operator And P a ge 2 2 455 D Control Pa nel Installation Manual wired to terminals 9 and 14, or radio control): EARNING OF PERATING IMES • When gate operator (1) reaches the position WARNING: During the learning procedure, the...
  • Page 23: Automated Systems Test

    November, 2003 400 Operat or And P a ge 2 3 455 D Control Pa nel Installation Manual The procedure has ended and the gate is ready to • When gate operator (2) reaches the position operate, using default slow down automatically set that you want it to slow down, an open by the control panel.
  • Page 24 November, 2003 400 Operator And P a ge 2 4 455 D Control Pa nel Installation Manual A (Automatic) Logic (455 D) Gate Status Open A Open B Stop Opening Closing Warning Light Reversing Reversing Device(s) Device(s) Opens single leaf...
  • Page 25 No effect No effect Stopped Closes the leaves Closes the leaf (opening is No effect opening is inhib- inhibited) ited) EP (Semi-automatic, Step by Step) Logic (455 D) Gate Status Open A Open B Stop Opening Closing Warning Reversing Reversing...
  • Page 26 November, 2003 400 Operator And P a ge 2 6 455 D Control Pa nel Installation Manual AINTENANCE 400 O PERATOR Change the oil. The FAAC recommended maintenance schedule varies Changing the oil requires removing the operator from its according to the frequency of use of the operators, installed position.
  • Page 27: Troubleshooting

    WARNING! Before you do any work on the control panel, be sure to turn off the main power. NOTE: Any control panel specific information in the following applies to the 455 D control panel only. If no reversing devices are installed, make sure a circuit...
  • Page 28: Limited Warranty

    Neither FAAC S.p.A. related systems and equipment manufactured by FAAC or FAAC International, Inc., shall be liable for any loss or S.p.A. and distributed by FAAC International, Inc., to be damage whatsoever resulting, directly or indirectly, free from defects in material and workmanship under from the use or loss of use of the product(s).

This manual is also suitable for:

400

Table of Contents

Save PDF