FAAC 402 Installation Manual

FAAC 402 Installation Manual

Operator and control panel
Hide thumbs Also See for 402:

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 402 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FAAC 402

  • Page 1: Table Of Contents

    N S T A L L A T I O N A N U A L CONTENTS Important Safety Information Technical Data Unpacking the Operator The 402 Compact Operator General Characteristics Installation Instructions Prepare the Gate Manual Release Mechanism Install the Operator Install the 455 D Control Panel...
  • Page 2: Important Safety Information

    November, 2003 402 Operator And P a ge 2 455 D Control Pa nel Installation Manual MPORTANT AFETY NFORMATION Both the installer and the owner and/or operator of this size of the gate, how often it is used, and how fast system need to read and understand this installation the gate operates.
  • Page 3 November, 2003 402 Operat or And P a ge 3 455 D Control Pa nel Installation Manual 6. It is extremely unsafe to compensate for a damaged • Do not install or operate the equipment gate by increasing hydraulic pressure.
  • Page 4: Technical Data

    Thermal cut out, deg F (deg C) 212 (100) Oil quantity, qt (liter) 1-1/2 (1.4) Oil type FAAC XD 220 or Shell/Tellus 15 Gate leaf constraints Maximum weight per leaf, lb (kg) 900 (410) Maximum length per leaf, ft (m)
  • Page 5: Unpacking The Operator

    P a ge 5 455 D Control Pa nel Installation Manual NPACKING THE PERATOR When you receive your 402 Compact Operator, complete Protective cover for the operator the following steps. End cap or guard cover Rear mounting bracket (for post or wall)
  • Page 6: The 402 Compact Operator General Characteristics

    The Manual Release Mechanism is a key operated device that disengages or engages the All models of the 402 operator have one hydraulic lock. hydraulic system of the 402 Operator. When the The CBC version is designed to lock when the piston is hydraulic system is disengaged, you can open and close extended.
  • Page 7: Manual Release Mechanism

    November, 2003 402 Operat or And P a ge 7 455 D Control Pa nel Installation Manual TTACH THE OUNTING RACKET Attach the rear mounting bracket according to the dimensions in Figure 4. WARNING! You must achieve the A and B dimensions, dimensions as specified in Figure 4.
  • Page 8 November, 2003 402 Operator And P a ge 8 455 D Control Pa nel Instal lation Manual as instructed below, will ensure proper location of the front mounting bracket. Once the operator is secure, install the protective cover over the piston of the operator, first insert the two...
  • Page 9: Install The 455 D Control Panel

    ANEL Locate the control panel in the most convenient position possible, considering the movement of the gate. Figure 6 shows a basic layout for a two-leaf gate with the 402 Compact Operator. Installing the control panel consists of the following general steps: •...
  • Page 10 November, 2003 402 Operator And P a ge 1 0 455 D Control Pa nel Installation Manual Figure 7. The layout of a sample gate system Locate switches at least 10 ft from the gate Operator Wire Gauges for Given Voltage...
  • Page 11: Exploded View, 402 Cbc

    November, 2003 402 Operat or And P a ge 1 1 455 D Control Pa nel Installation Manual , 402 CBC XPLODED...
  • Page 12: 402 Parts List

    November, 2003 402 Operator And P a ge 1 2 455 D Control Pa nel Installation Manual 402 P ARTS POS PART NO. DESCRIPTION PART NO. DESCRIPTION 2036 Galvanized Nut (8mm) 4404065 Inlet Valve 7220015 Rear Bracket O-Ring 7284005 Rear Bracket Plate...
  • Page 13 November, 2003 402 Operat or And P a ge 1 3 455 D Control Pa nel Installation Manual 4 5 5 D O N T R O L A N E L N S T A L L A T I O N A N U A L 1 4 —...
  • Page 14: The 455 D Control Panel General Description

    ESCRIPTION all applicable electrical codes. The installer should refer to the installation manual for a given operator for more The FAAC 455 D control panel is used to operate the information. following models. : An installation is U.L. compliant only...
  • Page 15: Connect The Operator To The Control Panel

    November, 2003 402 Operat or And P a ge 1 5 455 D Control Pa nel Installation Manual connect the white wire to terminal 4 (on the J4 ONNECT THE PERATOR TO THE terminal strip), the black wire to 5, the red wire to 6.
  • Page 16: Connect Other Devices

    The gate leaf (or leaves) should open. : UL does not recognize the FAAC system If a gate leaf closes, then you need to turn off the with loop detectors or safety edges. FAAC...
  • Page 17 (N.O.) contacts. Connect such devices to U.L. Listed gate terminals 9 and 14. operator(s) : The FAAC radio receiver plugs into the 5 prongs labeled J2 (Quick connect port). Page 19 shows how to connect a three or four wire OP_A...
  • Page 18: Set Other Operating Controls

    Turn the main power off before you The warning light is on steadily during OGIC make any electrical connections. opening and flashes during closing. For all FAAC hydraulic operators using the 455 D THER PERATING ONTROLS control panel, the force must be set at its maximum setting of 50 in order to supply the correct voltage to the operator.
  • Page 19 November, 2003 402 Operat or And P a ge 1 9 455 D Control Pa nel Installation Manual Magnetic Lock Free Exit Loop/ Phone/ Firebox (Hold Open Dev ices) Lock 12 vac Relay N.C. N.O. Shadow Loop FAAC Rev ersing Photocells...
  • Page 20: Programming

    November, 2003 402 Operator And P a ge 2 0 455 D Control Pa nel Installation Manual ROGRAMMING BASIC PROGRAMMING program automated system, “Programming Mode” must be accessed. Programming is split into two parts: BASIC and Display Function Default ADVANCED.
  • Page 21 November, 2003 402 Operat or And P a ge 2 1 455 D Control Pa nel Installation Manual ADVANCED PROGRAMMING Display Function fault NDICATOR ICHT If 0 is selected, the output functions as a standard indicator-light (lighted Display Function at opening and pause, flashing at closing, and off when gate closed).
  • Page 22: Learning Of Operating Times

    November, 2003 402 Operator And P a ge 2 2 455 D Control Pa nel Installation Manual • When gate operator (1) reaches the position EARNING OF PERATING IMES that you want it to slow down, an open command must be given to start the slow...
  • Page 23: Automated Systems Test

    November, 2003 402 Operat or And P a ge 2 3 455 D Control Pa nel Installation Manual The procedure has ended and the gate is ready to • When gate operator (2) reaches the position operate, using default slow down automatically set that you want it to slow down, an open by the control panel.
  • Page 24 November, 2003 402 Operator And P a ge 2 4 455 D Control Pa nel Installation Manual A (Automatic) Logic (455 D) Gate Status Open A Open B Stop Opening Closing Warning Light Reversing Reversing Device(s) Device(s) Opens single leaf...
  • Page 25 November, 2003 402 Operat or And P a ge 2 5 455 D Control Pa nel Installation Manual E (Semi-automatic) Logic (455 D) Gate Status Open A Open B Stop Opening Closing Warning Reversing Reversing Light Device(s) Device(s) Opens single leaf...
  • Page 26 Light duty use: every 12 mo PERATOR Heavy duty use: every 6 mo The FAAC recommended maintenance schedule varies according to the frequency of use of the operators, whether lightly used operators (once or twice an hour) HANGE THE OIL...
  • Page 27: Troubleshooting

    November, 2003 402 Operator And P a ge 2 7 455 D Control Pa nel Installat ion Manual ROUBLESHOOTING WARNING! Before you do any work on the control panel, be sure to turn off the main power. ROBLEM HE GATE DOES NOT OPEN...
  • Page 28: Faac International, Inc

    Neither FAAC S.p.A. S.p.A. and distributed by FAAC International, Inc., to be or FAAC International, Inc., shall be liable for any loss or free from defects in material and workmanship under damage whatsoever resulting, directly or indirectly, normal use and service for which it was intended from the use or loss of use of the product(s).

This manual is also suitable for:

455 d

Table of Contents