Standard
Description
SIA 281/3
Bitumen sheeting pull-off
testing
JGJ110
Construction Engineering dec-
orative tile Adhesive Strength
Testing Standard
JGJ126
The Exterior Decorative Brick
Construction and Inspection
Acceptance Standard
JGJ144
Exterior Insulation Engineering
Technical Standard

2.2 Proceq DY-2 Models

Three versions of Proceq DY-2 are available differentiated by maximum pulling force.
• Proceq DY-206 has increased accuracy for low strength applications. Recommended for elastic
surfaces due to higher requirement on load rate.
• Proceq DY-216 covering most applications. Recommended for elastic surfaces due to higher
requirement on load rate.
• Proceq DY-225 required for compliance with ASTM C 1583. Typically used for testing of fibre
reinforced polymers bonded to concrete structures.
The table below shows the recommended working range with a selection of test discs to help you
ascertain which model is most suited to your application.
Tensile Force
0.6 - 6 kN
Proceq
DY-206
135 - 1349 lbf
1.6 - 16 kN
Proceq
DY-216
360 - 3597 lbf
2.5 - 25 kN
Proceq
DY-225
562 - 5620 lbf
Note: The instrument begins to display and record measurement values from 0 kN.
4
Test disc
dia. 50mm 300
+/- 15 N/s
95x45x8mm,
40x40x8mm
100x100x8mm
Working Range
Test Disc Ø 50mm
0.3 - 3.1 MPa
44 - 443 psi
0.81 - 8.1 MPa
118 - 1182 psi
1.3 - 12.7 MPa
185 - 1847 psi
Specified load rate
(Proceq DY-206,
Proceq DY-216
recommended for
elastic surfaces)
Maximum
Pulling Speed
4.65 mm/min
0.183 inch/min
2.2 mm/min
0.086 inch/min