Typ
Overload pressure
Switching point
Max. switching point deflection under
temperature change
Hysteresis
Reproductibility
Operating voltage
Current at switching output with 30 V DC
Induced current consumption
Switching frequency
Electrical connection
Electromagnetic compatibility
Interference emitted
Immunity against interference
Protection class
Materials
Fig 22
2017-05e
PEV-W-S-LED-GH
PEV-W-KL-LED-GH
at P: max. 20 bar
Can be set from 2 ... 8 bar
≤ 200 mbar/10° K (with T = 0° C ... 23° C)
≤ 50 mbar/10° K (with T = 23° C ... 60° C)
0.5 ... 2 bar
± 0.3 bar
DC 10 ... 30 V, rated value DC 24 V
with Ω-load: 2,5 A, with inductive load: 2,5 A
25 mA
max. 3 Hz
bipolar connection possible
Tested as per DIN EN 61000-6-4 (industry)
Tested as per DIN EN 61000-6-2 (industry)
IP 65 as per IEC 529
IP 20 as per IEC 529
Housing:
PA, PET, POM
Pressure chamber:
AL, NBR, silicongel
Plugs:
CuZn chromium-plated, PA6
Screws:
ST zinccoated
Terminal strip:
CuZn, PA6
VPEV-W-S-LED-GH
VPEV-W-KL-LED-GH
at V: max. 8 bar
Can be set from -0.25 ... - 0.8 bar
≤ 15 mbar/10° K (with T = 0° C ... 23° C)
≤ 30 mbar/10° K (with T = 23° C ... 60° C)
0.08 ... 0.2 bar
± 0.08 bar
The component is intended for industrial use.
IP 65 as per IEC 529
IP 20 as per IEC 529
D/GB 15