UL Statement
- UL approved indoor mode and outdoor mode only.
Indoor high resolution mode and Indoor throw-in mode has not evaluated by UL.
- In case of using DC power supply
UL required the main unit to be connected to a UL listed power supply Class 2,
capable of providing a norminal input of 10.5-30 VDC 500 mA and battery standby
time of 4 hours.
- In case of using PoE injector or switch for power supply
UL required the main unit to be connected to a UL listed PoE injector or switch
and the PoE must be connected to a UL listed (UTRZ) UPS with output rating of
100-240 VAC, 1.0 A and 24 hours standby.
UL testing was conducted with product powered from the following Listed POE:
Manufacturer: PHIHONG, Model: POE36U-1AT-R, Input: 100-240 VAC, 1.0 A, Output: 56 V - 0.6 A
UL approved the PoE connection as supplemental.
The PoE cannot be used to monitor the device.
- For UL Listed installation applications
The relay outputs shall be connected to a compatible UL Listed control panel.
The signal input cannot be connected to alarm output to reduce the risk of
false alarm.
The equipment shall be installed in accordance with the National Electrical Code
NFPA 70.
- UL testing was conduted at temperature range of
0°C to 49°C for RLS-2020I, and -35°C to 66°C for RLS-2020S.
< MEMO >
Model/ Name
Place
Serial No.
Date
IP address/
Subnet mask/
Default gateway
Output 1
Output 2
Output 3
Input setting
Mode/
Parameter/
Others
EN 50131-1 Grades and Environmental Class:
Security Grade 3, Environment ClassII TS50131-2-11
■ EU contact information
Manufacturer:
OPTEX CO., LTD.
5-8-12 Ogoto, Otsu, Shiga,
520-0101 JAPAN
OPTEX INC./AMERICAS HQ (U.S.)
URL: www.optexamerica.com
OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
URL: www.optex-europe.com
OPTEX TECHNOLOGIES B.V.
(The Netherlands)
URL: www.optex.eu
Authorised representative in Europe:
OPTEX (EUROPE) LTD./EMEA HEADQUARTERS
Unit 13, Cordwallis Park, Clivemont Road,
Maidenhead Berkshire, SL6 7BU U.K.
OPTEX CO., LTD. (JAPAN)
URL: www.optex.net
OPTEX SECURITY SAS (France)
URL: www.optex-security.com
OPTEX SECURITY Sp.z o.o. (Poland)
URL: www.optex.com.pl
OPTEX PINNACLE INDIA,
PVT., LTD. (India)
URL: www.optex.net/in/en/sec
9
APPENDIX
9-1
REPAINTING
1
Remove the side cover cap, side cover L and side
cover Ss. (refer to 2-2 1 )
2
Remove the front cover. (refer to 3-1)
3
Remove the base cover. (refer to 2-2 2 3 4 )
2.
Note >>
Be careful not to lose the removed washer.
4
Paint the following parts. (refer to
Use the suitable paint for poly-carbonate resin.
Note >>
Do not paint the front cover, the laser window or the base unit.
Painting the RLS-2020 S a dark color could raise the internal
temperature and cause a malfunction.
Painting should be avoided if there is any possibility that
the unit would be exposed to direct sunlight.
EN-12
3.
1.
marks as follows)
OPTEX KOREA CO.,LTD. (Korea)
URL: www.optexkorea.com
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
URL: www.optexchina.com
OPTEX (Thailand) CO., LTD. (Thailand)
URL: www.optex.net/th/th
Copyright (C) 2018 OPTEX CO.,LTD.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rls-2020sRls-2020i

Table of Contents