List of synchronised base stations
All activated base stations contained in the Connected base stations list (
Base station synchronization list.
¤
Settings
For each registered base station the following information is shown:
MAC address
Base station
DM Name
Cluster
Sync Level
LAN Master
Sync Slave
Status
Cluster configuration
The page allows you to synchronise the system manually.
¤
Select the DECT manager you want to synchronise from the DM Name option menu . . . the
cluster configuration of the selected DECT manager is displayed below
Synchronising all clusters of the DECT manager
¤
Click on Synchronize all
Synchronising a specific cluster of the DECT manager
¤
From the Sync Slave option menu select which kind of synchronisation you want to perform
(LANor DECT)
www.internetvoipphone.co.uk | sales@internetvoipphone.co.uk | 0333 014 4343
Base stations
Synchronization
Hardware address of the base station. With this address the device is
uniquely identified within the LAN.
Name of the base station.
Name of DECT manager the base station belongs to.
Number of the cluster to which the base is assigned.
Synchronisation level within the sync hierarchy.
The base station acting as LAN master is marked by a
Indicates if the base station is synchronised via DECT or via LAN. For the Sync
master there is no entry in this column.
Synchronization status of the base station:
0
Offline
1
Deactivated
2
No Sync
3
Sync
4
Sync Overload
Click on Synchronize
Not available
Available but not activated
Activated but not synchronised
Activated and synchronised,
Synchronised but DECT overload
Base stations
p. 35) appear in the
.
45