Gigaset N870 IP PRO Installation, Configuration And Operation page 33

Multicell system
Table of Contents

Advertisement

Gigaset N870 IP PRO / ALL UK en / A31008-XXXXX-XXXX-X-XX / settings_DM.fm / 8/14/18
Actions
Adding a synchronization reference to the list
¤
Click on Add . . . the DECT manager synchronization page is opened (
Deleting a synchronization reference from the list
¤
Select the check box next to the sync reference you want to delete. Multiple choice is
possible.
Editing a synchronization reference
¤
Click on
ager synchronization page is opened (
Adding/Editing a synchronization reference
This page allows you to define which DECT device is responsible to synchronize a cluster man-
aged by the DECT manager. You can edit an existing entry of the DECT manager synchronization
table or add a new entry.
DM Name
¤
For a new entry: Select a DECT manager from the option menu.
For an existing entry the identifier is shown.
Cluster
¤
For a new entry: Select a cluster number of the selected DECT manager. Only one synchroni-
sation reference can be set for a cluster.
For an existing entry: The cluster number of the selected DECT manager is shown.
Cluster external sync
¤
Select the cluster's synchronisation reference:
No external sync
Best DECT base of DM
Ext RFPI xxx
LAN Master of DM
www.internetvoipphone.co.uk | sales@internetvoipphone.co.uk | 0333 014 4343
Click on Delete
Confirm with Yes . . . all selected sync references are deleted.
next to the DECT manager synchronization you want to edit . . . the DECT man-
Level 1 base of the cluster will only synchronise internally.
Level 1 base of the cluster will synchronise with the best accessible
base station of the DECT manager. The DECT manager must be
selected from the Reference option menu.
Level 1 base of the cluster will synchronise with another DECT sys-
tem. Different RFPI matching levels are possible.
Ext RFPI (full match) All bits of the RFPI are considered, i.e., one
Ext RFPI (-1 match)
Ext RFPI (-2 match)
. . .
The RFPI or a part of an RFPI must be entered in the Reference text
field. Matching base stations are used to synchronise.
Level 1 base of the cluster will synchronise with the LAN master of
the DECT manager. The DECT manager must be selected from the
Reference option menu.
DECT manager configuration
p. 28).
specific DECT system is referenced
-1 match: the last bit of the RFPI is ignored.
-2 match: the last two bits are ignored
. . .
p. 28).