Gigaset N870 IP PRO Installation, Configuration And Operation page 43

Multicell system
Table of Contents

Advertisement

Gigaset N870 IP PRO / ALL UK en / A31008-XXXXX-XXXX-X-XX / settings_basestations.fm / 8/14/18
Scenario 2:
Configuration: Pure DECT synchronisation. Each base station can synchronise with a base sta-
www.internetvoipphone.co.uk | sales@internetvoipphone.co.uk | 0333 014 4343
Pure DECT synchronisation
Use such a configuration if your environment ensures a stable DECT over the
air synchronisation or your LAN does not fulfil the requirements for LAN syn-
chronisation.
Prior to installation of base stations for DECT synchronisation, you should have
an idea, where in the centre to plan the level 1 base station and in which dis-
tances around the centre to place the next sync level's base station. To proof
and optimise this idea into a plan you should use a coverage measurement kit.
3
2
base 3
base 2
base 1
tion on a higher level. If more than one base station is possible the base station
with the better signal is used. The base station in the centre of the cluster is on
DECT level 1. That reduces the amount of necessary sync levels.
Base station
Cluster
1
1
2
1
3
1
4
1
5
1
6
1
7
1
DECT Level
1
2
base 4
base 5
base 6
DECT Level
LAN Master
3
2
2
2
1
2
3
Base stations
3
base 7
Sync Slave
DECT
DECT
DECT
DECT
DECT
DECT
43