Description of the motors
2.3 Derating factors
2.3
Derating factors
Under conditions other than those specified above (ambient temperature > 40° C or
installation altitude > 1000 m above sea level), the permissible torques/powers are shown in
the following table.
Ambient temperatures and installation altitudes are rounded off to 5° C or 500 m
respectively.
Table 2- 5
Installation altitude
above sea level in m
Factors x
The values required are provided in the M-n diagrams in the Configuration Manual for the
1FK7 G2.
Determine the reduced torque using the following formula:
M
red
x
×
D
You shift the S1 characteristic curve in parallel.
At installation altitudes of 2000 m above sea level or higher, the voltage stress on the motors
must be reduced accordingly based on the "Factors for reducing the maximum DC-link
voltage" table (reciprocal values from EN 60664-1 Table A. 2).
28
Power derating depending on the installation altitude and the ambient temperature (de-
rating factor x
)
D
1000
1.05
1500
1.02
2000
1.00
2500
0.97
3000
0.95
3500
0.92
4000
0.89
refer to static torque M
D
M
M
M
=
- (
- (
N
0
0
))
Ambient temperature in °C
30
35
1.02
1.00
1.00
0.97
0.97
0.95
0.95
0.92
0.92
0.89
0.89
0.87
0.87
0.84
.
0
M
/ Nm = reduced torque at rated speed
red
M
/ Nm = rated torque S1 (100K)
N
M
/ Nm = static torque (100K)
0
x
= derating factor
D
S-1FK7 DYA G2 synchronous motors with planetary gearbox
40
45
0.97
0.95
0.92
0.89
0.87
0.84
0.81
Operating Instructions, 05/2018, A5E44881183B AA
50
55
0.95
0.92
0.92
0.89
0.89
0.87
0.87
0.84
0.84
0.81
0.81
0.77
0.77
0.74